Proper Positioning for Elbow Obliques

Technologist positioning a patient's arm on an X-ray table for an oblique elbow X-ray

External Rotation Oblique When performing an external rotation oblique of the elbow, it’s critical that the shoulder, elbow, and wrist are all on the same plane. The elbow should be rotated externally about 45 degrees. While this can be challenging for some patients, this positioning provides the best view of the radial head, neck, and […]

Effective Communication with Radiologists and Radiology Staff

Close-up of a technologist's hand adjusting settings on a digital X-ray console displaying an ankle X-ray image

The Importance of Open Communication In any radiology department, strong communication builds trust and ensures the best outcomes for patients. Whether you’re interacting with radiologists or fellow technologists, being clear, honest, and open is essential. Be Honest and Accountable If you make a mistake—own it. Radiologists respect technologists who take responsibility for their actions. Admitting […]

Understanding the Deviation Index in Radiography

Clarkson College radiologic technology instructor standing in an exam room with an anatomical skeleton model in the background

What is the Deviation Index (DI)? The Deviation Index (DI) is a numerical tool used in radiography to determine whether an image is overexposed or underexposed. An acceptable DI range is between +3 and -3. Positive numbers indicate overexposure Negative numbers indicate underexposure In the film-screen era, technologists could assess exposure visually—overexposed images looked too […]

Advancing Your Career in PACS Administration

Axial MRI brain scan image in blue tones

What is PACS? PACS stands for Picture Archiving and Communication Systems—a critical technology in modern medical imaging. It allows healthcare providers to store, retrieve, manage, and share diagnostic images efficiently. The Role of a PACS Administrator A PACS administrator works closely with radiologists to ensure imaging workflow runs smoothly. Responsibilities include: Ensuring all imaging studies […]

Understanding Grid Errors in Radiography

Frontal chest X-ray image showing the lungs and ribcage

What is a Grid Error? Grid errors occur when the primary X-ray photons are absorbed by the lead strips within the grid instead of passing through to create the image. In digital radiography, this still results in an underexposed image. However, due to rescaling, the brightness may appear normal, making the error harder to detect. […]

Fujifilm Aspire Crystal Digital Mammography System

Fujifilm Aspire Cristalle 3D mammography system with a pink floral design on the housing

Over 9,000 customers worldwide rely on Fujifilm digital mammography systems. Known for forward-thinking technology and continuous innovation, Fujifilm remains committed to advancing breast imaging with brilliant image quality at low dose. Adaptive processing intelligently optimizes image quality for all breast types, including patients with implants.   Advanced Image Quality & Efficiency The Aspire Crystal is […]

When to Use Radiation Protection in Medical Imaging

Two radiologic technology students practicing X-ray positioning, one giving a thumbs up while the other operates the detector panel

The Importance of Shielding Radiation protection plays a critical role in patient safety and is a topic of ongoing discussion in the medical imaging profession. Proper shielding helps minimize unnecessary exposure while ensuring high-quality diagnostic images. When Shielding Is Appropriate Shielding should be used whenever possible, provided it does not obscure the anatomy being imaged. […]

Understanding the Roles in Medical Imaging

Clarkson College radiologic technology student standing in an exam room with an anatomical skeleton model in the background

X-Ray Technologist An X-ray technologist completes formal education in radiologic sciences and passes a certification exam administered by the ARRT (American Registry of Radiologic Technologists). Once certified and registered, they are trained to perform diagnostic imaging exams safely and accurately. X-Ray Technician A technician typically gains their skills through on-the-job training rather than formal education. […]

Advanced CT Imaging for Rural Communities

Fujifilm Scenaria View CT scanner with illuminated blue bore opening in a dimly lit exam room

The installation of a new 128-slice CT scanner means patients no longer need to travel out of town for advanced imaging. For rural communities, that’s a major win—saving time, reducing travel expenses, and eliminating the risks associated with long-distance trips for medical care. Built for All Patients This CT system features a larger gantry and […]

Shimadzu Rad Speed Pro: Versatile, Ergonomic, and Dose-Efficient

Technologist adjusting the control panel of a Shimadzu RADspeed Pro X-ray system in an exam room

The Shimadzu Rad Speed Pro is a fully integrated, high-performance X-ray system designed to work seamlessly with a variety of DR manufacturers — including Canon, Konica, and Fuji — based on customer preference. Its versatility, user-friendly controls, and dose-reduction features make it a trusted choice for both technologists and patients. Seamless Integration & Smart Workflow […]

Product Search